1. NDTQUAM industrial film processing chemical for automatic processor

| Type | Product | |
| H6 | fixure for machine A : 5L*2 B:0.5L*2 | Get 38L fluid |
| H7 | developer for machine A : 5L*2 B:0.5L*2 | Get 38L fluid |
The development temperature should be controlled at 26-30 ° C for 8-12 minutes
The fixing temperature is controlled at 26-28 ° C for 8-12 minutes.
Chemicals should be stored in their original packaging in a dry place at a temperature of+5~+20 ℃ and a relative humidity of 40~50%. The storage period should not exceed 24 months.
2. NDTQUAM industrial film processing chemical for manual processing
| Type | Product | |
| A6 | Developer 4L*2 | To make 40L processing solution |
| A7 | Fixer 4L*2 | To make 40L processing solution |
Processing conditions
Recommended standard development conditions:
| Temperature | Developing time |
| 18~24℃ | 3~5 Minutes |
Notice: The processing tank should be closed with cover.
Recommended standard fixing conditions:
| Temperature | Fixing time |
| 18~24℃ | 3~5 Minutes |
Storage
The chemicals should be stored in the original packing in a dry place at temperatures +5 to +25℃ and relative humidity 40 to 50% , for a period not exceeding 24 months.
3. FUHATA (FUJIFILM) Industrial X-ray film developer &fixer for manual processing

| Product | Type | Description | Dilution(with water) |
| developer & fixer for manual processing | 755203 | Developer 4L*2 | To make 40L processing solution |
| 755201 | Fixer 4L*2 | To make 40L processing solution |
Processing conditions
Recommended standard development conditions:
| Temperature | Developing time |
| 18~24℃ | 3~5 Minutes |
Notice: The processing tank should be closed with cover.
Recommended standard fixing conditions:
| Temperature | Fixing time |
| 18~24℃ | 3~5 Minutes |
Storage
The chemicals should be stored in the original packing in a dry place at temperatures +5 to +25℃ and relative humidity 40 to 50% , for a period not exceeding 24 months.
4. FUJIFILM Industrial X-ray film developer & fixer for automatic processor

| Product | Type | Description | Dilution(with water) |
| developer & fixer for automatic processor | 855303 | Developer A:5L*2 B:0.5L*2 BC:0.15L*2 | Get 38L processing solution |
| 855301 | FixerA:5L*2 B:0.5L*2 | Get 38L processing solution |
Note: After mixing, let it stand for two hours before use
Processing conditions
Recommended standard development conditions:
| Temperature | Developing time |
| 26~30℃ | 7-11 Minutes |
Recommended standard fixing conditions:
| Temperature | Fixing time |
| 26~2830℃ | 7-11 Minutes |
The chemicals should be stored in the original packing in a dry place at temperatures
+5 to +25℃ and relative humidity 40 to 50% , for a period not exceeding 24 months.
A possible crystalline fraction in parts A and C is not a defect. It will dissolve again
after heating to 40℃ and agitation the solution.